Drive system overview 1
13.2.4
How to set machine data and parameters
13
-6
For drive parameters MD3000-MD8999, data are to be displayed or entered with fractional
portion removed off so that they can be set also from the Digital Operator in the same way.
In this case, the unit displayed together indicates whether or not the data has frictional por-
tion.
MD3008 (Pn101) KVI (For each axis)
Meaning: Speed loop integration time constant setting
Setting value: [0.01 ms]
INFO